1 kV kabler
NOPOVIC N2XH 0,6/1 kV
N2XH is a top class halogen-free flame retardant cable with a copper conductor and insulation made of cross-linked halogen-free compound. The plastics used are characterized by a reaction to fire to CPR requirements of B2ca s1a d1 a1.
Key features:
· Voltage: 0.6/1 kV
· Temperature range: -40°C to +90°C (max. conductor temperature: +90°C, in case of short circuit: +250°C)
· Min. laying temperature: -5°C
· Compatibility: VDE 0276-604 5G, PN-EN 60332-1-2, PN-EN IEC 60332-3-24, PN-EN 61034-2, RoHS, REACH
Application:
Ideal for fixed indoor power installations under, in, on plaster, directly in concrete, for applications in facilities with a high concentration of people and/or electronic equipment.
Construction:
· Conductor: Copper class 1
· Insulation: Halogen-free, cross-linked
· Outer sheath: Black HFFR
Technical specifications:
· Cross-section range (1÷5)x(1.5÷240) mm2
· Insulation thickness: from 0.7 mm to 2.2 mm
· Outer sheath thickness: from 1.2 mm to 2.0 mm
· Outer diameter: from 5.2 mm to 54 mm
· Cable weight: from 40 kg/km to 9974 kg/km
Upgrade your installations with N2XH cables for the highest quality and performance. Available below: data sheet (including the current carrying capacity of N2XH cables), DoP declaration, CE declaration, EPD environmental declaration, certificate.
N2XH is a top class halogen-free flame retardant cable with a copper conductor and insulation made of cross-linked halogen-free compound. The plastics used are characterized by a reaction to fire to CPR requirements of B2ca s1a d1 a1.
Key features:
· Voltage: 0.6/1 kV
· Temperature range: -40°C to +90°C (max. conductor temperature: +90°C, in case of short circuit: +250°C)
· Min. laying temperature: -5°C
· Compatibility: VDE 0276-604 5G, PN-EN 60332-1-2, PN-EN IEC 60332-3-24, PN-EN 61034-2, RoHS, REACH
Application:
Ideal for fixed indoor power installations under, in, on plaster, directly in concrete, for applications in facilities with a high concentration of people and/or electronic equipment.
Construction:
· Conductor: Copper class 1
· Insulation: Halogen-free, cross-linked
· Outer sheath: Black HFFR
Technical specifications:
· Cross-section range (1÷5)x(1.5÷240) mm2
· Insulation thickness: from 0.7 mm to 2.2 mm
· Outer sheath thickness: from 1.2 mm to 2.0 mm
· Outer diameter: from 5.2 mm to 54 mm
· Cable weight: from 40 kg/km to 9974 kg/km
Upgrade your installations with N2XH cables for the highest quality and performance. Available below: data sheet (including the current carrying capacity of N2XH cables), DoP declaration, CE declaration, EPD environmental declaration, certificate.